bta41-200 bta41-400 bta41-600 bta41-800 BTA41-1000 bta41-1200 v drm v 200 400 600 800 1000 1200 v dsm v 220 450 700 900 1100 1300 symbol test conditions maximum ratings unit t vj =80 41 a t vj =45 o c t=10ms (50hz), sine v r =0 t=8.3ms (60hz), sine t vj =t vjm t=10ms(50hz), sine v r =0 t=8.3ms(60hz), sine 420 400 350 320 a i tsm t vj =45 o c t=10ms (50hz), sine v r =0 t=8.3ms (60hz), sine t vj =t vjm t=10ms(50hz), sine v r =0 t=8.3ms(60hz), sine 880 850 760 720 a 2 s i 2 t (di/dt) cr 50 300 a/us (dv/dt) cr t vj =t vjm ; v dr =2/3v drm r gk = ; method 1 (linear voltage rise) 500 v/us p gm t vj =t vjm t p =30us i t =i tavm t p =300us 10 5 w p gav 1 w i trms o c t vj t vjm t stg -40...+125 125 -40...+125 v isol 50/60hz, rms t=1minute, leads-to-tab 2500 v~ m d mounting torque (m4) 0.8...1.5 nm weight 6 g t vj =t vjm repetitive, i t =40a f=50hz, t p =200us v d =2/3v drm i g =0.3a non repetitive, i t =i tavm di g /dt=0.3a/us v rgm 10 v o c unit:mm t2 t1 g min max min max a 0.81 0.835 20.57 21.21 b 0.61 0.63 15.49 16 c 0.178 0.188 4.52 4.78 d 0.055 0.07 1.4 1.78 e 0.487 0.497 12.37 12.62 f 0.635 0.655 16.13 16.64 g 0.022 0.029 0.56 0.74 h 0.075 0.095 1.91 2.41 j 0.575 0.625 14.61 15.88 k 0.211 0.219 5.36 5.56 l 0.422 0.437 10.72 11.1 m 0.058 0.068 1.47 1.72 n 0.045 0.055 1.14 1.4 p 0.095 0.115 2.41 2.92 o 0.008 0.016 0.2 0.41 r 0.008 0.016 0.2 0.41 u 0.159 0.163 4.04 4.14 w 0.085 0.095 2.17 2.42 dim. inches millimeter t1 t2 g bta41-200 thru bta41-1200 discrete traics (isolated) http://www.luguang.cn mail:lge@luguang.cn
symbol t est conditions characteristic v alues unit v v tm i t =41a; t vj =25 o c 1.44 v to for power-loss calculations only (t vj =125 o c) 0.85 v r t 10 m v gt 1.3 v v d =6v; i t =1a;t vj =25 o c i gt 50 ma v gd t vj =t vjm ; v d =2/3v drm 0.2 v i gd 10 ma i h t vj =25 o c; v d =6v; r gk = 100 ma dc current r thjc 1.3 k/w dc current r thjh 1.5 k/w a max. acceleration, 50 hz 50 m/s 2 i r , i d t vj =t vjm ; v d =v drm 10 ma v d =6v; i t =1a;t vj =25 o c 50 50 100 1.3 1.3 1.5 bta41-200 thru bta41-1200 discrete traics (isolated) http://www.luguang.cn mail:lge@luguang.cn
fig. 1: maximum power dissipation versus rms on-state current (full cycle). fig. 2: rms on-state current versus case temperature (full cycle). 0 5 1 0 1 5 2 0 2 5 3 0 3 5 41 0 1 0 2 0 3 0 4 0 50 it(rms) (a) p (w) 1 8 0? 0 25 50 75 1 0 0 1 2 5 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 4 5 tc(c) it(rms) (a) = 1 8 0? fig. 3: relative variation of thermal impedance versus pulse duration. fig. 4: on-state characteristics (maximum values). fig. 5: surge peak on-state current versus n umber of cycles. f ig. 6: non-repetitive surge peak on-state c urrent for a sinusoidal pulse with width t p < 10 ms, and corresponding value of i2t. 1.e-03 1.e-02 1.e-01 1.e+00 1.e+01 1.e+02 1.e+03 1.e-03 1.e-02 1.e-01 1.e+00 k=[zth/rth] z th (j-c ) tp (s ) 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 1 10 100 400 vtm (v) itm (a) t j= 2 5?c t j m a x tj max.: vto = 0.85 v rd = 10 m ? 1 10 100 1000 0 50 100 150 200 250 300 350 400 450 number of c ycles itsm (a) non repetitive tj initial=25c r e p e titiv e t c = 7 0?c o n e c y c le t= 2 0 m s 0.01 0.10 1.00 10.0 0 100 1000 10000 tp (ms) itsm (a), i2t (a2s) tj initial=25c it s m i2t d i/d t lim ita tio n : 5 0 a / s bta41-200 thru bta41-1200 discrete traics (isolated) http://www.luguang.cn mail:lge@luguang.cn
fig. 7: relative variation of gate trigger current, holding current and latching current versus j unction temperature (typical values). f ig. 8: relative variation of critical rate of decrease of main current versus (dv/dt)c (typical values). -40 -20 0 20 40 60 80 100 120 140 0.0 0.5 1.0 1.5 2.0 2.5 tj(c) igt,ih,il[tj] / igt ,ih,il [tj=25c] igt ih & il 0.1 1.0 10.0 100.0 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 (dv/dt)c (v/s) (di/dt)c [(dv/dt)c] / specified (di/dt)c fig. 9: relative variation of critical rate of decrease of main current versus junction t emperature. 0 25 50 75 100 125 0 1 2 3 4 5 6 tj (c) (di/dt)c [tj] / (di/dt)c [tj specified] bta41-200 thru bta41-1200 discrete traics (isolated) http://www.luguang.cn mail:lge@luguang.cn
symbol t est conditions characteristic v alues unit v v tm i t =41a; t vj =25 o c 1.44 v to for power-loss calculations only (t vj =125 o c) 0.85 v r t 10 m v gt 1.3 v v d =6v; i t =1a;t vj =25 o c i gt 50 ma v gd t vj =t vjm ; v d =2/3v drm 0.2 v i gd 10 ma i h t vj =25 o c; v d =6v; r gk = 100 ma dc current r thjc 1.3 k/w dc current r thjh 1.5 k/w a max. acceleration, 50 hz 50 m/s 2 i r , i d t vj =t vjm ; v d =v drm 10 ma v d =6v; i t =1a;t vj =25 o c 50 50 100 1.3 1.3 1.5 bta41-200 thru bta41-1200 discrete traics (isolated) http://www.luguang.cn mail:lge@luguang.cn
|